Please use this identifier to cite or link to this item:
http://hdl.handle.net/10603/7125
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.coverage.spatial | Physics | en_US |
dc.date.accessioned | 2013-02-27T09:51:31Z | - |
dc.date.available | 2013-02-27T09:51:31Z | - |
dc.date.issued | 2013-02-27 | - |
dc.identifier.uri | http://hdl.handle.net/10603/7125 | - |
dc.description.abstract | The Design Development and Application of Computer Assisted Pedicle Screw fixation by a novel method for accurate placement of pedicle screws is proposed. The location and orientation of the pedicle screws are clinically important in pedicle screw fixation. In the proposed technique, the point of insertion is determined using the image slices of diagnostic CT. The orientation of the pedicle screw is determined by processing the video streams captured online during fhe surgical process using two digital cameras. Mathematical morphology based techniques are employed for screw segmentation and Hough Transform for angle deferminution. This is a very less expensive system wifh a personal computer and two digital cameras, and can be assembled on demand uccessfully. The system has proved to have clinical precision required for spine surgery and extremely useful in medical education field for surgery training. | en_US |
dc.format.extent | 230p. | en_US |
dc.language | English | en_US |
dc.relation | - | en_US |
dc.rights | university | en_US |
dc.title | Design development and application of computer assisted pedicle screw fixation | en_US |
dc.title.alternative | - | en_US |
dc.creator.researcher | John, P S | en_US |
dc.subject.keyword | rnuthematlcal morphology | en_US |
dc.subject.keyword | Pedicle screw flxdon | en_US |
dc.subject.keyword | Physics | en_US |
dc.subject.keyword | computer usslsfed spine surgery | en_US |
dc.description.note | References given chapters wise | en_US |
dc.contributor.guide | Menon, C S | en_US |
dc.publisher.place | Kottayam | en_US |
dc.publisher.university | Mahatma Gandhi University | en_US |
dc.publisher.institution | School of Pure and Applied Physics | en_US |
dc.date.registered | n.d. | en_US |
dc.date.completed | 2008 | en_US |
dc.date.awarded | n.d. | en_US |
dc.format.dimensions | - | en_US |
dc.format.accompanyingmaterial | None | en_US |
dc.type.degree | Ph.D. | en_US |
dc.source.inflibnet | INFLIBNET | en_US |
Appears in Departments: | School of Pure and Applied Physics |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
01_title.pdf | Attached File | 20.47 kB | Adobe PDF | View/Open |
02_declaration.pdf | 19.72 kB | Adobe PDF | View/Open | |
03_certificate.pdf | 29.9 kB | Adobe PDF | View/Open | |
04_acknowledgements.pdf | 28.24 kB | Adobe PDF | View/Open | |
05_abstract.pdf | 29.64 kB | Adobe PDF | View/Open | |
06_preface.pdf | 231.05 kB | Adobe PDF | View/Open | |
07_contents.pdf | 71.76 kB | Adobe PDF | View/Open | |
08_list of tables.pdf | 24.58 kB | Adobe PDF | View/Open | |
09_list of figures.pdf | 114.74 kB | Adobe PDF | View/Open | |
10_chapter 1.pdf | 2.1 MB | Adobe PDF | View/Open | |
11_chapter 2.pdf | 1.26 MB | Adobe PDF | View/Open | |
12_chapter 3.pdf | 408.55 kB | Adobe PDF | View/Open | |
13_chapter 4.pdf | 618.5 kB | Adobe PDF | View/Open | |
14_chapter 5.pdf | 1.83 MB | Adobe PDF | View/Open | |
15_chapter 6.pdf | 1.37 MB | Adobe PDF | View/Open | |
16_chapter 7.pdf | 356.83 kB | Adobe PDF | View/Open | |
17_chapter 8.pdf | 1.63 MB | Adobe PDF | View/Open | |
18_chapter 9.pdf | 211.89 kB | Adobe PDF | View/Open | |
19_chapter 10.pdf | 87.87 kB | Adobe PDF | View/Open |
Items in Shodhganga are licensed under Creative Commons Licence Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0).
Altmetric Badge: