Please use this identifier to cite or link to this item: http://hdl.handle.net/10603/599262
Title: Design and synthesis of schiff and chalcone based fluorescent chemosensor for selective cation detection and its application in biological and real sample analysis
Researcher: Summaya Banu, B
Guide(s): Hemalatha, K V
Keywords: Chemistry
Chemistry Analytical
fluorescent chemosensor
Physical Sciences
real sample analysis
schiff and chalcone
University: Anna University
Completed Date: 2024
Abstract: In supramolecular chemistry the development of chemosensor has newlinereceived a lot of interest in the identification and detection of metal ions in newlinebiological and environmental materials. Metal ions are identified using a variety newlineof analytical tools such as atomic absorption spectrometry, voltammetry, and newlineion-coupled plasma emission-mass spectrometry and ion selective electrodes. newlineThe fluorescence approach is one of the newly developing techniques. The first newlinechapter, discuss about the principle of chemosensor, design of chemosensor newlinedifferent mechanism involved in chemosensors and so on. newlineThe second chapter, discusses about various chemosensor such as newlinerhodamine-quinoline, squarin, indazole, naphthalic anhydride, coumarin, newlinenapthol, newlineaminobenzoic acid, triazole, naphtalimide, terepthalic acid, newlinesalicylimine, newlinephenol, newlinedinitrobenzene, newlineimidazophenanthroline, newlinepyrene, newlinepyrimidine, newlineoxadiazole, newlinenaphthalene, newlinedimethylaminocinnamaldehyde newlineaminothiourea, anthracene, benzoindo-croconine, Benzothiazole, sodium newlinebenzene sulfonate, carbazole, tripodal for selective and specific detection of newlinecation such as Al3+, Fe2+, Ag+ and Fe3+ metal ion. The third chapter, explains newlineabout the materials and methodology used to synthesize 2-hydroxy-1 newlinenaphthaldehyde-2-aminothiazole, 2-aminothiazolesalicylaldehyde, 2-hydroxy-1 newlinenaphthaldehyde sulphanilic acid, p-Dimethyl-1,3-Diphenylprop-2-en-1-one. newlineThe schiff based condensation and aldol condensation method was used to newlinesynthesize four different chemosensor. The prepared chemosensor was newlinecharacterized by various technique such as FTIR, 13C and H1 NMR and mass newlinespectroscopy. The binding between chemosensor and various metal ion was newlinestudied via fluorescence spectroscopy. The fourth chapter, explains about the newlinedetection of various metal ions using synthesized material in the biological and newlineenvironmental condition newline
Pagination: xxv,155p.
URI: http://hdl.handle.net/10603/599262
Appears in Departments:Faculty of Science and Humanities

Files in This Item:
File Description SizeFormat 
01_title.pdfAttached File198.5 kBAdobe PDFView/Open
02_prelim pages.pdf2.89 MBAdobe PDFView/Open
03_content.pdf572.88 kBAdobe PDFView/Open
04_abstract.pdf53.13 kBAdobe PDFView/Open
05_chapter1.pdf878.86 kBAdobe PDFView/Open
06_chapter2.pdf523.35 kBAdobe PDFView/Open
07_chapter3.pdf375.76 kBAdobe PDFView/Open
08_chapter4.pdf1.74 MBAdobe PDFView/Open
09_chapter5.pdf1.75 MBAdobe PDFView/Open
10_chapter6.pdf2.79 MBAdobe PDFView/Open
11_chapter7.pdf1.9 MBAdobe PDFView/Open
12_chapter8.pdf140.78 kBAdobe PDFView/Open
13_annexures.pdf172.55 kBAdobe PDFView/Open
80_recommendation.pdf151.5 kBAdobe PDFView/Open
Show full item record


Items in Shodhganga are licensed under Creative Commons Licence Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0).

Altmetric Badge: