Please use this identifier to cite or link to this item: http://hdl.handle.net/10603/594153
Full metadata record
DC FieldValueLanguage
dc.coverage.spatialDesign of predictive and biologically inspired controllers in a four legged shunt active power filter
dc.date.accessioned2024-10-10T09:19:28Z-
dc.date.available2024-10-10T09:19:28Z-
dc.identifier.urihttp://hdl.handle.net/10603/594153-
dc.description.abstractThe usage of electronic units has grown stealthily in the past few newlinedecades. This has directly impacted the power quality of the network by newlinetarnishing the power flow with harmonics. Harmonics is one of the leading newlinepower quality issue prevailing in any power system. Globally, the Institute of newlineElectrical and Electronics Engineers (IEEE) put forth the harmonics newlineregulatory standard IEEE Std. 519-2014. The standard imposes acceptable newlineharmonic limits in the line-utility interface. Although the International newlineElectrotechnical Commission (IEC) recommends the mitigation of voltage newlineharmonics when it exceeds limits, the IEEE standards insist on the newlinemeasurement of current harmonics periodically. When too many end users newlinedraw harmonic current from the same voltage source, it would gradually newlineincrease the voltage harmonic level. Hence, the Central Electricity Authority newline(CEA) in India, endorses practices to mitigate current harmonics that exceeds newlinelimits. With their notion to make a healthy and harmonic-free grid, certain newlinepenalty mechanism has been deployed for the customers who violate the newlineharmonic regulatory standards. newlineThe Tamil Nadu Electricity Regulatory Commission (TNERC) newlineendorses the harmonic limits set by CEA Regulation 2007 (Technical newlinestandards for connectivity to the grid). The Total Harmonic Distortion (THD) newlineof voltage should be within 5% at the Point of Common Coupling (PCC) and newlinethe THD of current should not exceed 8%. Some of the common practices that newlineaddresses harmonic issues are the utilisation of filters at the point of common newlinecoupling. newline
dc.format.extentxxviii,171p.
dc.languageEnglish
dc.relationp.160-170
dc.rightsuniversity
dc.titleDesign of predictive and biologically inspired controllers in a four legged shunt active power filter
dc.title.alternative
dc.creator.researcherJoe Brislin, J
dc.subject.keywordelectronic units
dc.subject.keywordEngineering
dc.subject.keywordEngineering and Technology
dc.subject.keywordEngineering Electrical and Electronic
dc.subject.keywordgrown stealthily
dc.subject.keywordInstitute of Electrical and Electronics Engineers
dc.description.note
dc.contributor.guideSundaram, M
dc.publisher.placeChennai
dc.publisher.universityAnna University
dc.publisher.institutionFaculty of Electrical Engineering
dc.date.registered
dc.date.completed2024
dc.date.awarded2024
dc.format.dimensions21cm.
dc.format.accompanyingmaterialNone
dc.source.universityUniversity
dc.type.degreePh.D.
Appears in Departments:Faculty of Electrical Engineering

Files in This Item:
File Description SizeFormat 
01_title.pdfAttached File138.6 kBAdobe PDFView/Open
02_prelim pages.pdf1.48 MBAdobe PDFView/Open
03_content.pdf40.68 kBAdobe PDFView/Open
04_abstract.pdf34.09 kBAdobe PDFView/Open
05_chapter1.pdf270.66 kBAdobe PDFView/Open
06_chapter2.pdf1.78 MBAdobe PDFView/Open
07_chapter3.pdf1.71 MBAdobe PDFView/Open
08_chapter4.pdf1.17 MBAdobe PDFView/Open
09_chapter5.pdf1.15 MBAdobe PDFView/Open
10_annexures.pdf128.63 kBAdobe PDFView/Open
80_recommendation.pdf136.97 kBAdobe PDFView/Open


Items in Shodhganga are licensed under Creative Commons Licence Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0).

Altmetric Badge: