Please use this identifier to cite or link to this item: http://hdl.handle.net/10603/545891
Title: Certain investigations on PH process station for neutralization and remote monitoring using IOT
Researcher: Dharshan, Y
Guide(s): Srinivasan, K
Keywords: cleansing and cooling
Engineering
Engineering and Technology
Engineering Environmental
ground water and source
water resources
University: Anna University
Completed Date: 2024
Abstract: The earth constitutes of 71% of water as its major area, in forms of newlineoceans, glaciers and ice, ground water and source from mountains, in which newline3.4% of the water is being used by the people for domestic purposes. Water is newlinealso used in industries for different applications, for the purposes of newlinemanufacturing, cleansing and cooling requirements. As per the statistical newlinereport industries utilize water and also pollute the source in the form of wastes newlinethat are formed in the processes. newlineThe government has proposed various measures and constraints for the newlineindustries for the disposal of the waste water into the water resources. One newlinesuch important parameter to be considered before disposal is the pH, which newlinedefines the concentration of the hydrogen ions (H+ newline) and hydroxide ions (OH- newline) newlinein the water that makes it either Acidic (high quantity of H+ newline ions), Alkaline newline(high quantity of OH- newline ions) or Neutral state. newlineNeutralization is the process of converting or maintaining the process newlineliquid at a pH value of 7. To neutralize the liquid pH, additives are utilized newline(i.e) when the liquid is found to have acidic nature, alkaline solution is added newlineand vice versa is carried out if the liquid is found alkaline. Additives are newlineadded to the process liquid using the various final control elements using newlinesuitable control system. The control system gets the information from the set newlinepoint and compares the data from the pH sensor to control the amount of newlineadditive to be added through the control element. newlineThe basic control systems utilized in industries for the pH process are newlineProportional Integral (PI) controller and simple ON-OFF controller. In this newlineresearch work, controllers such as conventional PI controller tuned using newlineZiegler Nichlos (ZN), Tyres Luben (TL) and Internal Model Control newlineiv newlinetechniques are proposed for tuning the controller gain values. newline
Pagination: xx,161
URI: http://hdl.handle.net/10603/545891
Appears in Departments:Faculty of Electrical Engineering

Files in This Item:
File Description SizeFormat 
01_title.pdfAttached File26.15 kBAdobe PDFView/Open
02_prelim pages.pdf2.6 MBAdobe PDFView/Open
03_content.pdf633.71 kBAdobe PDFView/Open
04_abstract.pdf182.82 kBAdobe PDFView/Open
05_chapter1.pdf2.78 MBAdobe PDFView/Open
06_chapter2.pdf8 MBAdobe PDFView/Open
07_chapter3.pdf933.84 kBAdobe PDFView/Open
08_chapter4.pdf858.58 kBAdobe PDFView/Open
09_chapter5.pdf855.01 kBAdobe PDFView/Open
10_chapter6.pdf901.76 kBAdobe PDFView/Open
11_chapter7.pdf543.98 kBAdobe PDFView/Open
12_annexures.pdf174.88 kBAdobe PDFView/Open
80_recommendation.pdf95.04 kBAdobe PDFView/Open
Show full item record


Items in Shodhganga are licensed under Creative Commons Licence Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0).

Altmetric Badge: