Please use this identifier to cite or link to this item: http://hdl.handle.net/10603/545549
Title: Certain improvements in source current harmonics reduction for an induction motor with shunt active filter
Researcher: Sivakumar A
Guide(s): Muthu Selvan N B
Keywords: Electromagnetic interferences
Engineering
Engineering and Technology
Engineering Electrical and Electronic
Induction motor
Shunt Active Filter
Source current harmonics reduction
University: Anna University
Completed Date: 2018
Abstract: The recent developments in the power electronic fields have newlineattracted more applications of non-linear loads such as adjustable speed newlinedrives, traction drives, UPS, battery chargers, etc. These loads have inherently newlineintroduced the harmonics in the tied power system and cause many power newlinequality issues like electromagnetic interferences (EMI), malfunctioning of newlinerelays and circuit breakers, de-rating of power devices, heating losses and their newlineassociated problems. The harmonics are to be eliminated or reduced by using newlinepower filters with proper control techniques. In many research articles, the newlineknown method of shunt active filters being introduced in the PCC and load newlineend has been reported. This research work has demonstrated the performance newlineenhancement of VSI fed induction motor by introducing a new scheme of newlineShunt Active Filter (SAF) at the supply end. The SAF performs the reduction newlineof source current harmonics due to non-linear load like VSI fed three phase newlineinduction motor. The instantaneous active and reactive current control newlinetechniques have been implemented and studied using different controllers. newlineShunt active filter has been used to generate the equal but opposite harmonic newlinecurrents to cancel the effects of harmonic currents drawn by the non-linear newlineload from the supply. The proposed system has been studied with PI, PID, newlineFuzzy logic, ANN and Fractional order PID controllers. The main goal of this newlineresearch work is to enhance the power quality by the way of reducing the newlinesupply current harmonic THDs. The proposed research work has been newlinesimulated using MATLAB software and its simulation results have been newlineverified by the experimental results. The results have indicated a low source newlinecurrent harmonic THD of 2.72% owing to the introduction of the shunt active newlinefilter on the supply side and closed loop control. newline newline
Pagination: xx, 137p.
URI: http://hdl.handle.net/10603/545549
Appears in Departments:Faculty of Electrical Engineering

Files in This Item:
File Description SizeFormat 
01_title.pdfAttached File24.59 kBAdobe PDFView/Open
02_prelim_pages.pdf672.83 kBAdobe PDFView/Open
03_contents.pdf11.71 kBAdobe PDFView/Open
04_abstracts.pdf8.56 kBAdobe PDFView/Open
05_chapter1.pdf152.1 kBAdobe PDFView/Open
06_chapter2.pdf258.45 kBAdobe PDFView/Open
07_chapter3.pdf332.15 kBAdobe PDFView/Open
08_chapter4.pdf594.22 kBAdobe PDFView/Open
09_chapter5.pdf180.51 kBAdobe PDFView/Open
10_annexures.pdf110.42 kBAdobe PDFView/Open
80_recommendation.pdf68.64 kBAdobe PDFView/Open
Show full item record


Items in Shodhganga are licensed under Creative Commons Licence Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0).

Altmetric Badge: