Please use this identifier to cite or link to this item: http://hdl.handle.net/10603/475022
Full metadata record
DC FieldValueLanguage
dc.coverage.spatialPharmacy
dc.date.accessioned2023-04-06T10:43:14Z-
dc.date.available2023-04-06T10:43:14Z-
dc.identifier.urihttp://hdl.handle.net/10603/475022-
dc.description.abstractquotMethod: 1 A sensitive, rapid, precise and accurate RP-HPLC method has been developed for simultaneous estimation of Hydroquinone and Glycolic Acid from their Cream Formulation. The Chromatographic separation was achieved on a reversed-phase Inertsil C18 (4.6 mm I.D. × 250 mm, 5 µm) column using a mobile phase consisting of Buffer (pH 3) -Acetonitrile in the ratio of 95:05% V/V at a flow rate of 0.5mL/min and UV detection at and#955;max 277 nm. The method showed linearity with regression coefficient of Hydroquinone and Glycolic Acid was 0.9991 and 0.9994 over the range of 2-12 µg/mL, 10-60 µg/mL respectively. The mean recoveries were found to be in the range of 99.00 101.00 % for all the components. The method was validated as per the ICH guidelines for linearity, limit of detection, limit of quantification, specificity, accuracy, less precision and robustness. The method can be successfully applied for routine analysis of quantitative determination of Hydroquinone and Glycolic Acid in pharmaceutical dosage form. newlineMethod: 2and3 A simple, sensitive, rapid, precise and accurate RP-HPLC method has been developed for simultaneous estimation of Hydroquinone, Hydrocortisone and Tretinoin from their Cream Formulation. The Chromatographic separation was achieved on a reversed-phase InertsilC18 (4.6 mm I.D. × 250 mm, 5 µm) column using a mobile phase consisting of Buffer (pH 4) 0.05M Potassium Dihydrogen Ortho Phosphate-Methanol in the ratio of 80:20% V/V at a flow rate of 1mL/min and UV detection at and#955;max 243 nm. The method showed linearity with regression coefficient of Hydroquinone, Hydrocortisone and Tretenoin was 0.9994, 0.9995 and 0.9994 over the range of 40-120 µg/mL, 20-60 µg/mL and 0.25-0.75 µg/mL respectively. The mean recoveries were found to be in the range of 99.00 101.00% for all the components. The method was validated as per the ICH guidelines for linearity, limit of detection, limit of quantification, specificity, accuracy, precision and robustness. The method can be successfully applied for routine analysis of
dc.format.extent-
dc.languageEnglish
dc.relationNo of References 48
dc.rightsuniversity
dc.titleDevelopment and validation of an analytical methods for estimation of anti acne drugs with in combination of hydroquinone in topical formulation
dc.title.alternative
dc.creator.researcherShilu, Rakshaben K.
dc.subject.keywordAllantoin Hydrocortisone
dc.subject.keywordAnalytical Method Development
dc.subject.keywordAnalytical Method Validation Degradation study
dc.subject.keywordClinical Pre Clinical and Health
dc.subject.keywordGlycolic Acid
dc.subject.keywordHydroquinone
dc.subject.keywordPharmacology and Pharmacy
dc.subject.keywordPharmacology and Toxicology
dc.subject.keywordTretenoin and Kojic Acid
dc.description.noteReferences p. 214-218
dc.contributor.guideKapupara, Pankaj
dc.publisher.placeRajkot
dc.publisher.universityRK University
dc.publisher.institutionFaculty of Pharmacy
dc.date.registered2018
dc.date.completed2023
dc.date.awarded2023
dc.format.dimensions-
dc.format.accompanyingmaterialNone
dc.source.universityUniversity
dc.type.degreePh.D.
Appears in Departments:Faculty of Pharmacy

Files in This Item:
File Description SizeFormat 
01_title page.pdfAttached File8.51 kBAdobe PDFView/Open
02_prelim pages.pdf279.7 kBAdobe PDFView/Open
03.list of abbrivation.pdf41.01 kBAdobe PDFView/Open
04_abstract & graphical abstract.pdf101.89 kBAdobe PDFView/Open
05_chapter 1.pdf433.6 kBAdobe PDFView/Open
06_chapter 2.pdf107.98 kBAdobe PDFView/Open
07_chapter 3.pdf42.43 kBAdobe PDFView/Open
08_chapter 4.pdf133.9 kBAdobe PDFView/Open
09_chapter 5.pdf940.4 kBAdobe PDFView/Open
10_chapter 6.pdf5.25 MBAdobe PDFView/Open
11_chapter 7.pdf515.13 kBAdobe PDFView/Open
12_annexures.pdf279.79 kBAdobe PDFView/Open
13_urkund report(only first page).pdf1.54 MBAdobe PDFView/Open
80_recommendation.pdf442.29 kBAdobe PDFView/Open


Items in Shodhganga are licensed under Creative Commons Licence Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0).

Altmetric Badge: