dc.coverage.spatialVibration analysis of quasi zero stiffness vibration isolator with composite material
dc.date.accessioned2023-04-03T14:40:01Z-
dc.date.available2023-04-03T14:40:01Z-
dc.identifier.urihttp://hdl.handle.net/10603/474456-
dc.description.abstractCharacteristics are a trending and impressive approach to attenuate undesirable vibration. There is a limit in the isolation performance of the existing models of QZS vibration isolators, which are used with either helical coil springs or Euler s buckled beam resulted in unstable dynamic response while lowering vibration frequencies. To enhance the damping performance of the QZS vibration isolator, it is recommended to use double-acting hydraulic cylinders (fluidic actuators in short) to absorb the dynamic vibrational frequencies. Fluidic actuator contributes to the vital role on diminishing vibrational frequencies with less amplitude and adopting the system to various static loading conditions by adjustable damping factors. This Research work develops a QZS Vibration isolator designed with fluidic actuators. To this research associates two types of vibration isolators. The first model was designed and developed with fluidic actuators in oblique and helical coil spring in vertical directions as Quasi Zero Stiffness Vibration Isolator with Fluidic Actuators and Helical Coil Spring (QZSFA-HC) system, an approximate solution of the unique analytical relationship between the stiffness of the vertical spring and the bulk modulus of the fluid is derived. For characteristic analysis, the force transmissibility is formulated, and the damping ratio is explored. A modal analysis is done and compared to analytical data, as well as the development and investigation of an experimental prototype. The QZSFA-HC decreases external discomfort more at low frequencies, and a series of experimental tests have shown that soft non - linearity limits the resonant frequency, resulting in improved isolation, and the QZSFA-HC outperformed linear isolators by lowering vibrational frequencies. newline
dc.format.extentxxii,132.
dc.languageEnglish
dc.relationP.121-131p.
dc.rightsuniversity
dc.titleVibration analysis of quasi zero stiffness vibration isolator with composite material
dc.title.alternative
dc.creator.researcherSivakumar S
dc.subject.keywordEngineering and Technology
dc.subject.keywordEngineering
dc.subject.keywordEngineering Mechanical
dc.description.note
dc.contributor.guideJayakumar, L
dc.publisher.placeChennai
dc.publisher.universityAnna University
dc.publisher.institutionFaculty of Mechanical Engineering
dc.date.registered
dc.date.completed2021
dc.date.awarded2021
dc.format.dimensions21cm
dc.format.accompanyingmaterialNone
dc.source.universityUniversity
dc.type.degreePh.D.
Appears in Departments:Faculty of Mechanical Engineering

Files in This Item:
File Description SizeFormat 
01_title.pdfAttached File25.24 kBAdobe PDFView/Open
02_prelim pages.pdf792.3 kBAdobe PDFView/Open
03_content.pdf409.23 kBAdobe PDFView/Open
04_abstract.pdf107.93 kBAdobe PDFView/Open
05_chapter 1.pdf617.18 kBAdobe PDFView/Open
06_chapter 2.pdf188.63 kBAdobe PDFView/Open
07_chapter 3.pdf622.91 kBAdobe PDFView/Open
08_chapter 4.pdf1.25 MBAdobe PDFView/Open
09_chapter 5.pdf1.51 MBAdobe PDFView/Open
10_chapter 6.pdf454.05 kBAdobe PDFView/Open
11_annextures.pdf131.84 kBAdobe PDFView/Open
80_recommendation.pdf67.49 kBAdobe PDFView/Open


Items in Shodhganga are licensed under Creative Commons Licence Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0).

Altmetric Badge: