Please use this identifier to cite or link to this item: http://hdl.handle.net/10603/452498
Title: Detection and Classification of Faults in Power System Incorporating Facts Devices for Stability Enhancement
Researcher: Rao, Gururaja H V
Guide(s): Prabhu, Nagesh
Keywords: Engineering
Engineering and Technology
Engineering Electrical and Electronic
University: Visvesvaraya Technological University, Belagavi
Completed Date: 2020
Abstract: Modern Power Systems generally operate under more stressed conditions due to continuous newlineincrease in demand for electrical energy and Right of Way and other constraints on new newlinetransmission lines. Hence it is challenging for power system engineers to efficiently utilize existing newlinetransmission facilities. Power flow through existing transmission lines can be increased and the newlinelines can be loaded close to their thermal limits by the use of FACTS controllers in the line. Voltage newlineSource Converter (VSC) based FACTS controllers have several advantages over conventional newlineFACTS controllers based on thyristors. The series connected FACTS controller, SSSC is useful in newlineincreasing the power flow through the line. STATCOM is a shunt connected FACTS controller newlinewhich is helpful for better voltage regulation and damping oscillations. newlineVSC based FACTS controllers has an additional advantage of incorporating an energy newlinestorage device at the DC bus. This facilitates real power exchange with the network and hence it newlineis possible to control the reactive and real power flow in a better way. However, compensating newlinelines with FACTS controllers incorporating energy storage device poses new challenges for the newlineoperation and control of power system. Designing a reliable and fast acting protection system for newlinesuch systems, ensuring the transient stability of the system is a challenging task for the protection newlineengineer. newlineOperation and control of FACTS controllers with energy storage modifies the apparent newlineimpedance measured by conventional distance relay and a detailed investigation is necessary to newlinestudy the impact of FACTS controllers with energy storage device on the performance of distance newlinerelay. There is hardly any reported work on the emulated reactance and resistance by SSSC and newlineemulated conductance and susceptance by STATCOM with four quadrant operation and its impact newlineon the operation of distance relay. This thesis presents the detailed model of SSSC with energy newlinestorage (SSSC ES) and STATCOM with energy storage (STATCOM ES
Pagination: XIX, 176
URI: http://hdl.handle.net/10603/452498
Appears in Departments:Nitte Mahalinga Adyanthaya Memorial Institute of Technology

Files in This Item:
File Description SizeFormat 
01_title.pdfAttached File474.93 kBAdobe PDFView/Open
02_prelim pages.pdf1.14 MBAdobe PDFView/Open
03_content.pdf486.2 kBAdobe PDFView/Open
04_abstract.pdf295.5 kBAdobe PDFView/Open
05_chapter 1.pdf641.26 kBAdobe PDFView/Open
06_chapter 2.pdf814.17 kBAdobe PDFView/Open
07_chapter 3.pdf1.82 MBAdobe PDFView/Open
08_chapter 4.pdf1.93 MBAdobe PDFView/Open
09_chapter 5.pdf1.24 MBAdobe PDFView/Open
10_annexures.pdf782.2 kBAdobe PDFView/Open
11_chapter 6.pdf1.03 MBAdobe PDFView/Open
80_recommendation.pdf311.71 kBAdobe PDFView/Open
Show full item record


Items in Shodhganga are licensed under Creative Commons Licence Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0).

Altmetric Badge: