dc.description.abstractRapid growth in industry and automation drive has introduced diverse sensitive loads in newlineelectrical domain. These sensitive loads require uniform power to be fed without any perturbations. These sensitive loads are vulnerable to even small variations in voltage. This is critical in life newlinesupport systems, cyber physical systems where data is very critical. These situations have changed the ways of traditional power generation and distribution sectors. The end users have started expecting high quality power to be delivered to them as the loads on their side are sensitive in newlinenature. A single stop solution to this changed requirements is the concept of Custom Power Park (CPP). A CPP can be defined as an entity with a dedicated power network which procures power from various power generating companies or grids and with the help of Custom Power Devices (CPD), improve the quality of power and deliver the end users the power with their required power newlinequality.The proposed work focuses on design and development of a Custom Power Park which newlineprovides customized service with high quality, regulated, uninterrupted, steady and clean electrical power service as per the customer demand with the help of custom power devices. The performance of various Custom Power Devices such as Solid State Transfer Switch(SSTS), Static synchronous Compensator (STATCOM) / Shunt Active Filter and Dynamic Voltage Restorer (DVR) / Series Active Filter are analyzed. The functions of Shunt Active Filter such as Current newlineharmonic compensation, Reactive power compensation and balancing of unbalanced load currents need to be analyzed to ensure load compensation. The performance of the Series Active Filter to maintain a constant load voltage profile under all the kinds of voltage perturbations has to be newlineverified. In the research work, a novel and efficient controller for Series Active Filter to carry out compensation of voltage sag, swell, harmonics, magnitude and phase unbalance has been proposed. Performance analysis of prototype versions of the proposed..
dc.format.extentxxi, 160
dc.languageEnglish
dc.relation
dc.rightsuniversity
dc.titleDesign and Development of a Mini Custom Power Park with Power Quality Improvement
dc.title.alternative
dc.creator.researcherManitha P V
dc.subject.keywordEngineering
dc.subject.keywordEngineering and Technology
dc.subject.keywordEngineering Electrical and Electronic; Smart Grid; Solid State Transfer Switch; Renewable Energy; CustomPower Park
dc.description.note
dc.contributor.guideManjula G Nair
dc.publisher.placeCoimbatore
dc.publisher.universityAmrita Vishwa Vidyapeetham University
dc.publisher.institutionDepartment of Electrical and Electronics Engineering
dc.date.registered2013
dc.date.completed2020
dc.date.awarded2020
dc.format.dimensions
dc.format.accompanyingmaterialNone
dc.source.universityUniversity
dc.type.degreePh.D.
Appears in Departments:Department of Electrical and Electronics Engineering

Files in This Item:
File Description SizeFormat 
01_title.pdfAttached File32.36 kBAdobe PDFView/Open
02_prelims pages.pdf183.73 kBAdobe PDFView/Open
03_content.pdf89.99 kBAdobe PDFView/Open
04_abstract.pdf52.88 kBAdobe PDFView/Open
05_chapter 1.pdf142.79 kBAdobe PDFView/Open
06_chapter 2.pdf101.62 kBAdobe PDFView/Open
07_chapter 3.pdf177.56 kBAdobe PDFView/Open
08_chapter 4.pdf329.52 kBAdobe PDFView/Open
09_chapter 5.pdf2.97 MBAdobe PDFView/Open
10_chapter 6.pdf2.05 MBAdobe PDFView/Open
11_annexures.pdf2.89 MBAdobe PDFView/Open
80_recommendation.pdf99.32 kBAdobe PDFView/Open


Items in Shodhganga are licensed under Creative Commons Licence Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0).

Altmetric Badge: