Please use this identifier to cite or link to this item: http://hdl.handle.net/10603/423859
Full metadata record
DC FieldValueLanguage
dc.coverage.spatial
dc.date.accessioned2022-12-09T10:57:23Z-
dc.date.available2022-12-09T10:57:23Z-
dc.identifier.urihttp://hdl.handle.net/10603/423859-
dc.description.abstractA methodology is proposed to solve the load flow solution of radial and meshed distribution networks using Fuzzy-PSO. To reduce the effective loss of the system, an approach for optimal DG size has been computed using a hybrid ABC-CS algorithm. The locations of DG units are the principal reasons for placement of DGs in the electric radial distribution networks. These investigations allow another deterministic technique that decides exact location for DG arrangement. The exact nodes for DG placement have been computed using the loss sensitive factors. The multi DG placement have given better results compared to the single DG placement. The proposed method has been implemented on 33-node, 69-node radial and 85-node meshed distribution networks and the results obtained by the proposed method have been compared with the other existing methods. In this thesis an exact voltage stability index (VSI) has been proposed considering the voltage angle. The VSI indices have been calculated using the proposed load flow solution. The voltage stability indices obtained by the proposed method with other two existing VSI indices have been compared. The VSI values have also been computed before and after DG placement. The above three distribution networks have been considered for the computation of VSI using the proposed VSI index and by the existing VSI indices. The placement of only multi DGs cannot give the major loss reduction. Also, it is true that only the network reconfiguration cannot give the sufficient loss reduction. The network reconfiguration along with the multi DG placement in the reconfigured networks can give the better results. The hybrid algorithm ABC-CS is used here for network reconfiguration. The results obtained by the proposed method have also been compared with the other existing methods. The proposed method gives better results compared to the other existing methods. newline
dc.format.extent144p.
dc.languageEnglish
dc.relation
dc.rightsuniversity
dc.titleStable Optimal Planning of Electric Power Distribution System using Fuzzy Logic
dc.title.alternative
dc.creator.researcherBala, Rajni
dc.subject.keywordEngineering
dc.subject.keywordEngineering and Technology
dc.subject.keywordEngineering Electrical and Electronic
dc.subject.keywordFuzzy logic
dc.description.note
dc.contributor.guideGhosh, Smarajit
dc.publisher.placePatiala
dc.publisher.universityThapar Institute of Engineering and Technology
dc.publisher.institutionDepartment of Electrical and Instrumentation Engineering
dc.date.registered
dc.date.completed2020
dc.date.awarded2020
dc.format.dimensions
dc.format.accompanyingmaterialNone
dc.source.universityUniversity
dc.type.degreePh.D.
Appears in Departments:Department of Electrical and Instrumentation Engineering

Files in This Item:
File Description SizeFormat 
01_title.pdfAttached File159.96 kBAdobe PDFView/Open
02_prelim pages.pdf1.94 MBAdobe PDFView/Open
03_content.pdf227.02 kBAdobe PDFView/Open
04_abstract.pdf150.26 kBAdobe PDFView/Open
05_chapter 1.pdf499.29 kBAdobe PDFView/Open
06_chapter 2.pdf2.02 MBAdobe PDFView/Open
07_chapter 3.pdf867.11 kBAdobe PDFView/Open
08_chapter 4.pdf1.1 MBAdobe PDFView/Open
09_chapter 5.pdf410.38 kBAdobe PDFView/Open
10_annexures.pdf616.3 kBAdobe PDFView/Open
80_recommendation.pdf565.8 kBAdobe PDFView/Open


Items in Shodhganga are licensed under Creative Commons Licence Attribution-NonCommercial 4.0 International (CC BY-NC 4.0).

Altmetric Badge: