Title: Experimental investigation on Energy conservation in Air conditioning system using Nanofluid cooled condenser
Researcher: Chandraprabu V
Guide(s): Sankaranarayanan G
Keywords: Nanofluid cooled condenser
Process control Vapour
Upload Date: 20-Mar-2015
University: Anna University
Completed Date: 01/08/2014
Abstract: Air conditioners are widely used in for personal comfort and newlineprocess control Vapour compression refrigeration system occupy over 90 newlineof the applications Due to environmental problems refrigerant R12 has been newlinephased out and R22 is in pipeline Efforts are ongoing to find out a suitable newlinealternative to R22 Efforts are made to improve the performance of small as newlinewell as large capacity systems Air conditioners with compact size are now newlinenecessary for many applications In order to obtain the compactness of air newlineconditioners smaller size of heat exchanger and high heat transfer fluid are newlineneeded But conventional air conditioners have heat exchangers of larger size newlinealong with heat removal fluids of lower heat capacity To achieve high heat newlinetransfer rate the thermal behavior of the fluid must be changed Metals and newlinemetal oxides have high capacity in heat transfer, so suspension of nanometer newlinesized metal oxide particles really improves the performance of base fluid newlineInduced nanoparticles improve the thermal conductivity of the base fluid and newlineso the thermal performance of base fluid increases In this direction in the newlinepresent research work performance of small capacity 0 75 TR R22 newlinesystems are tested with air cooled and water cooled condenser to enhance the newlineperformance the effect of retrofitting R22 system with R410A and R407C newlineand energy conservation in air conditioning system by introducing newlineAl2O3 water and CuO water nanofluid cooled condenser are studied newlineAn experimental facility has been created as per BIS standard 1391 newlineThe facility has a test window air conditioner of 2 46 kW capacity with aircooled newlineWater cooled and nanofluid cooled condenser newline newline
Pagination: xxxix, 194p.
URI: http://hdl.handle.net/10603/37709
Appears in Departments:Faculty of Mechanical Engineering

Files in This Item:
File Description SizeFormat 
01_title.pdfAttached File63.66 kBAdobe PDFView/Open
02_certificate.pdf395.93 kBAdobe PDFView/Open
03_abstract.pdf23.58 kBAdobe PDFView/Open
04_acknowledgement.pdf23.16 kBAdobe PDFView/Open
05_content.pdf78.03 kBAdobe PDFView/Open
06_chapter1.pdf59.79 kBAdobe PDFView/Open
07_chapter2.pdf80 kBAdobe PDFView/Open
08_chapter3.pdf36.06 kBAdobe PDFView/Open
09_chapter4.pdf1.15 MBAdobe PDFView/Open
10_chapter5.pdf13.4 MBAdobe PDFView/Open
11_chapter6.pdf5.37 MBAdobe PDFView/Open
12_chapter7.pdf122.89 kBAdobe PDFView/Open
13_chapter8.pdf847.72 kBAdobe PDFView/Open
14_chapter9.pdf27.65 kBAdobe PDFView/Open
15_appendix.pdf925.19 kBAdobe PDFView/Open
16_reference.pdf63.97 kBAdobe PDFView/Open
17_publication.pdf22.47 kBAdobe PDFView/Open
Show full item record


Items in Shodhganga are licensed under Creative Commons Licence Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0).

Altmetric Badge: