Please use this identifier to cite or link to this item: http://hdl.handle.net/10603/332764
Title: Performance study on pmsg based grid connected wind energy conversion system with non linear feedback controllers
Researcher: Sebastian Vindro Jude P
Guide(s): Mahalakshmi, R
Keywords: Wind energy conversion
Photovoltaic Boards
H-bridge multilevel inverter
University: Anna University
Completed Date: 2020
Abstract: People around are abundantly worried about the non-renewable energy source depletion and the ecological issues caused by the conventional power generation. So people are moving to renewable power sources and among them Photovoltaic Boards and wind-generators are broadly utilized at present. Wind sources are used today in numerous applications, for example, battery charging, water pumping, home power supply, swimming-pool heating frameworks, satellite power frameworks, and so on. They have the benefit of being support and contamination-free, however, their establishment cost is high in many applications. The share of wind power concerning the total installed power capacity is increasing worldwide. The Permanent Magnet Synchronous Generator (PMSG) based wind turbine with a variable-speed variable-pitch control scheme is the most popular wind power generator in the wind power industry. This machine can be operated either in grid-connected or standalone mode. A thorough understanding of the modeling, control, and dynamic as well as the steady-state analysis of this machine in both operation modes is necessary to optimally extract the power from the wind and accurately predict its performance. The strategies differ in complexity, sensors required, combination speed, cost, the scope of effectiveness, usage equipment, popularity, and in various regards. To mitigate the issues, different control calculations are produced to accomplish maximum power from the Wind Energy Conversion System (WECS) under variable speed conditions. In this work, the three advanced methods are proposed to dynamic characterises from the WECS integrated grid. In the first method is Firefly Algorithm (FA) and Artificial Neural Network (ANN) algorithms are used to attain the optimal pulses of cascaded H-bridge multilevel inverter. With optimized design parameters, the grid integrated power system design attained a voltage THD of 11.47%. newline
Pagination: xviii,142p.
URI: http://hdl.handle.net/10603/332764
Appears in Departments:Faculty of Electrical Engineering

Files in This Item:
File Description SizeFormat 
01_title.pdfAttached File20.23 kBAdobe PDFView/Open
02_certificates.pdf441.86 kBAdobe PDFView/Open
03_vivaproceedings.pdf383.12 kBAdobe PDFView/Open
04_bonafidecertificate.pdf92.66 kBAdobe PDFView/Open
05_abstracts.pdf112.04 kBAdobe PDFView/Open
06_acknowledgements.pdf319 kBAdobe PDFView/Open
07_contents.pdf158.62 kBAdobe PDFView/Open
08_listoftables.pdf126.82 kBAdobe PDFView/Open
09_listoffigures.pdf185.69 kBAdobe PDFView/Open
10_listofabbreviations.pdf177.99 kBAdobe PDFView/Open
11_chapter1.pdf1.22 MBAdobe PDFView/Open
12_chapter2.pdf407.24 kBAdobe PDFView/Open
13_chapter3.pdf1.24 MBAdobe PDFView/Open
14_chapter4.pdf1.03 MBAdobe PDFView/Open
15_chapter5.pdf1.14 MBAdobe PDFView/Open
16_chapter6.pdf204.96 kBAdobe PDFView/Open
17_conclusion.pdf204.96 kBAdobe PDFView/Open
18_references.pdf1.15 MBAdobe PDFView/Open
19_listofpublications.pdf241.17 kBAdobe PDFView/Open
80_recommendation.pdf170.49 kBAdobe PDFView/Open
Show full item record


Items in Shodhganga are licensed under Creative Commons Licence Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0).

Altmetric Badge: