Please use this identifier to cite or link to this item: http://hdl.handle.net/10603/324389
Title: Drug Infusion Algorithm for Closed Loop Anesthetic Drug Delivery System Satisfying Patient Safety Constraints
Researcher: Shola Usha Rani
Guide(s): Neelanarayanan, V
Keywords: Computer Science
Computer Science Interdisciplinary Applications
Engineering and Technology
University: VIT University
Completed Date: 2020
Abstract: The digital world moves healthcare and medicine into future advances of scientific technologies.These technologies will emerge as fundamental potential changes in modern patient safety systems. One of the examples of interest is closed-loop anesthesia delivery system. Before the advancement of the automatic drug delivery system, the anesthesia procedure was administrated manually. To explore and implement safer injection of anesthesia new advancement of automated closed -loop anesthesia delivery system is introduced. It is an automatic system which is capable of administering anesthesia procedure more safely than the manual infusion procedures. There are many problems involved during these procedures. The system is suffering from many limitations like patient variability, where the system behaves uniquely to all patients; possibility of occurring adverse events and errors; this system is even not supporting the patient safety features, it is not commercially acceptable by the medical regular bodies and the system could not sense the physical status of the patient. Another major challenge of this medicine is the infusion of dosage levels of overdose; it leads to the undesirable side effects of cardiorespiratory depression. Based on these major challenges, the system needs to newlineknow the correct amount of anesthetic drug to be infused to the patient based on the levels of conscious state by considering patient demographic data and his/her fitness while maintaining the other vital parameters. There are multiple parameters considered for closed-loop anesthesia delivery but the Bispectral index (BIS) is one of the important measures used to indicate the level of hypnotic states based on the drugs infused in closed-loop delivery system. This helps the researchers and practitioners to control the level of anesthesia and to automate the drug administration.The objective of this study is to demonstrate the closed loop anesthesia delivery (CLAD) system with patient safety measures through computer simulations. The proposed sy
Pagination: i-xii, 1-110
URI: http://hdl.handle.net/10603/324389
Appears in Departments:School of Computing Science and Engineering -VIT-Chennai

Files in This Item:
File Description SizeFormat 
01_title page.pdfAttached File218.05 kBAdobe PDFView/Open
02_signed copy of declaration & certificate.pdf549.58 kBAdobe PDFView/Open
03_abstract.pdf391.15 kBAdobe PDFView/Open
04_content.pdf393.49 kBAdobe PDFView/Open
05_list of tables.pdf390.46 kBAdobe PDFView/Open
06_list of figures.pdf394.2 kBAdobe PDFView/Open
07_acknowledgement_.pdf389.83 kBAdobe PDFView/Open
08_chapter-01.pdf247.78 kBAdobe PDFView/Open
09_chapter-02.pdf329.38 kBAdobe PDFView/Open
10_chapter-03.pdf363.23 kBAdobe PDFView/Open
11_chapter-04.pdf533.48 kBAdobe PDFView/Open
12_chapter-05.pdf973.19 kBAdobe PDFView/Open
13_chapter-06.pdf1.43 MBAdobe PDFView/Open
14_chapter-07.pdf770.91 kBAdobe PDFView/Open
15_chapter-08.pdf86.8 kBAdobe PDFView/Open
16_list of publications.pdf388.51 kBAdobe PDFView/Open
17_references.pdf398.99 kBAdobe PDFView/Open
18_appendix.pdf446.68 kBAdobe PDFView/Open
80_recommendation.pdf295.1 kBAdobe PDFView/Open
Show full item record


Items in Shodhganga are licensed under Creative Commons Licence Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0).

Altmetric Badge: