Title: Studies on retrofitting an r22 window airconditioner with hfc hc refrigerant mixture
Researcher: Herbert raj M
Guide(s): Mohan lal D
Keywords: mechanical engineering
refrigerant mixture
window airconditioner
Upload Date: 24-Dec-2014
University: Anna University
Completed Date: 01/09/2009
Abstract: The commonly used refrigerant in unitary type airconditioners is newlineR22 and its phase out schedule in developing countries is to commence from newline2015 Many alternatives to R22 are found in published literature The M20 newlinerefrigerant mixture is one such alternative with specific advantages The M20 newlineis a refrigerant mixture of R407C R600a and R290 in the mass fraction newline801096904 respectively The M20 refrigerant mixture has characteristics newlinesimilar to those of R22 with an exception of the temperature gliding during newlinethe phase change process at a constant pressure due to its zeotropic nature In newlinethe present study experiments have been conducted in a window newline newline
Pagination: xxix, 249p.
URI: http://hdl.handle.net/10603/31662
Appears in Departments:Faculty of Mechanical Engineering

Files in This Item:
File Description SizeFormat 
01_title.pdfAttached File37.18 kBAdobe PDFView/Open
02_certificate.pdf5.88 kBAdobe PDFView/Open
03_abstract.pdf11.87 kBAdobe PDFView/Open
04_acknowledgement.pdf6.72 kBAdobe PDFView/Open
05_contents.pdf62.53 kBAdobe PDFView/Open
06_chapter 1.pdf135.95 kBAdobe PDFView/Open
07_chapter 2.pdf256.4 kBAdobe PDFView/Open
08_chapter 3.pdf196.45 kBAdobe PDFView/Open
09_chapter 4.pdf5.08 MBAdobe PDFView/Open
10_chapter 5.pdf1.51 MBAdobe PDFView/Open
11_chapter 6.pdf112.79 kBAdobe PDFView/Open
12_references.pdf53.94 kBAdobe PDFView/Open
13_publications.pdf6.71 kBAdobe PDFView/Open
14_vitae.pdf6.25 kBAdobe PDFView/Open
Show full item record


Items in Shodhganga are licensed under Creative Commons Licence Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0).

Altmetric Badge: