Title: Experimental investigations on the performance of environmentally friendly refrigerant mixtures in a vapour compression refrigeration system as alternative to CFC12 and HFC134a
Researcher: Mani K
Guide(s): Selladurai V
Keywords: CFC12
HFC134a
Mechanical engineering
Refrigerant mixtures
Refrigeration system
Vapour compression refrigeration system
Upload Date: 13-Oct-2014
University: Anna University
Completed Date: 01/06/2008
Abstract: Today s refrigeration and air conditioning industries are moving towards chlorine and fluorine free working fluids as chlorine is one of the important causative agents for ozone layer depletion and fluorine is responsible for global warming CFC12 the generally accepted and more suitable refrigerant for vapour compression refrigeration system was phased out by 1996 in developed countries and has to be phased out by 2010 in developing countries because of its high ozone depletion potential and global warming potential HFC134a has been suggested to replace CFC12 in vapour compression refrigeration systems HFCs are used with polyolester oil only as it is immiscible with the conventional mineral oil The POE oil is highly hygroscopic and makes the system vulnerable to problems due to moisture entry Hydrofluorocarbons are safer to ozone layer but it has high global warming potential Kyoto Protocol aimed at reducing the overall emissions of green house gases by at least 5 below 1990 level in the commitment period 2008 to 2012 For this reason, the production and use of HFC134a will be terminated in the near future Millions of refrigeration systems heat pumps and air conditioners all over the world operating with CFC12 and HFC134a have to be retrofitted suitably in the event of the above phase out However very few studies exist on the replacement of HFC134a refrigerant This has motivated to study the newlineperformance of vapour compression refrigeration system with some of the available environment friendly fluids as replacements for CFC12 and HFC134a newline
Pagination: xxii,191p.
URI: http://hdl.handle.net/10603/26581
Appears in Departments:Faculty of Mechanical Engineering

Files in This Item:
File Description SizeFormat 
01_title.pdfAttached File60.51 kBAdobe PDFView/Open
02_certificate.pdf6.01 kBAdobe PDFView/Open
03_abstract.pdf15.16 kBAdobe PDFView/Open
04_acknowledgement.pdf7.06 kBAdobe PDFView/Open
05_contents.pdf33.86 kBAdobe PDFView/Open
06_chapter1.pdf67.99 kBAdobe PDFView/Open
07_chapter2.pdf118.79 kBAdobe PDFView/Open
08_chapter3.pdf60.51 kBAdobe PDFView/Open
09_chapter4.pdf90.82 kBAdobe PDFView/Open
10_chapter5.pdf4.14 MBAdobe PDFView/Open
11_chapter6.pdf269.82 kBAdobe PDFView/Open
12_chapter7.pdf158.44 kBAdobe PDFView/Open
13_chapter8.pdf8.57 MBAdobe PDFView/Open
14_chapter9.pdf16.84 kBAdobe PDFView/Open
15_appendix.pdf79.95 kBAdobe PDFView/Open
16_references.pdf46.42 kBAdobe PDFView/Open
17_publications.pdf8.74 kBAdobe PDFView/Open
18_vitae.pdf6.49 kBAdobe PDFView/Open
Show full item record


Items in Shodhganga are licensed under Creative Commons Licence Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0).

Altmetric Badge: