Please use this identifier to cite or link to this item: http://hdl.handle.net/10603/256628
Title: Performance Comparison of Various Control Strategies of Impedence Souce Inverter Fed Power Supply Unit for Remote Area
Researcher: Sivaganesan S.
Guide(s): D. Kirubakaran
University: Vels University
Completed Date: 
Abstract: This work deals with simulation and implementation of AC-AC converter for wind newlinegeneration. The AC output of the wind generator is converted into DC using three phase newlineuncontrolled rectifier. The output of the rectifier is filtered using Z-impedance network. The newlineoutput of the z-network is applied to the three phase inverter which feeds an induction motor newlineload. Wind generator system modal was developed in Simulink. The simulation was carried newlineusing MATLAB and the simulation results were obtained. The hardware was tested and the newlineexperimental results were obtained. The experimental results were compared with the newlinesimulation results. newlineThis work also proposes Quasi Z source inverter (QZSI) for AC-AC conversion in newlinewind generation system. This work presents modeling and simulation of QZ-source based AC newlineto AC converter system. The DC source is obtained by using wind generator and rectifier. newlineThe output of QZS network is applied to three phase inverter which feeds an induction motor newlineload. The simulation studies were performed using MATLAB and results were presented. newlineThe hardware was fabricated and tested. The experimental results were compared with the newlinesimulation results. newlineFurther work was carried out on Switched Inductance QZ Source inverter (SI-QZSI) newlinefor AC-AC conversion involving wind generation system. Modeling and simulation of SIQZSI newlinebased AC to AC converter system was also been extensively done. newlineIn this thesis, the possibility of using SI-QZI source inverter with different control newlinetechnique like Single pulse, Sine PWM, and Trapezoidal PWM for AC to AC conversion is newlinealso explored in the wind generation system. The proposed system has advantage like newlinereduced hardware and increased voltage gain less harmonic. SI-QZSI was introduced newlinebetween the rectifier and the inverter of AC to AC converter system. This system was newlinedesigned, modeled, simulated and implemented in the laboratory and the experimental results newlinewere obtained. newlineA comparison was made in different PWM techniques such as Single pulse, Sine newlinePWM and Trapezoidal PWM.
Pagination: 
URI: http://hdl.handle.net/10603/256628
Appears in Departments:School of Engineering

Files in This Item:
File Description SizeFormat 
abbreviation.pdfAttached File77.62 kBAdobe PDFView/Open
abstract.pdf75.32 kBAdobe PDFView/Open
acknowledgement.pdf76.14 kBAdobe PDFView/Open
certificate.pdf215.83 kBAdobe PDFView/Open
chapter1.pdf114.68 kBAdobe PDFView/Open
chapter2.pdf337.43 kBAdobe PDFView/Open
chapter3.pdf208.77 kBAdobe PDFView/Open
chapter4.pdf619.78 kBAdobe PDFView/Open
chapter5.pdf1.18 MBAdobe PDFView/Open
chapter6.pdf987.09 kBAdobe PDFView/Open
chapter7.pdf959.72 kBAdobe PDFView/Open
chapter8.pdf200.89 kBAdobe PDFView/Open
chapter9.pdf162.25 kBAdobe PDFView/Open
content.pdf200.69 kBAdobe PDFView/Open
list of publications.pdf158.91 kBAdobe PDFView/Open
references.pdf187.16 kBAdobe PDFView/Open
title.pdf258.55 kBAdobe PDFView/Open
Show full item record


Items in Shodhganga are licensed under Creative Commons Licence Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0).

Altmetric Badge: