Please use this identifier to cite or link to this item: http://hdl.handle.net/10603/233879
Title: Analysis and compensation of current harmonics using three level voltage source inverter based shunt active power filter
Researcher: Patel, P.J.
Guide(s): Patel, R.M.
Keywords: Digital Signal Processor
Engineering and Technology,Engineering,Engineering Electrical and Electronic
Fast Fourier Transform
Neutral Point Clamped
PI Based Current Control Method
PSIM
Shunt Active Power Filter
Space Vector Current Control Method
Three Level Voltage Source Inverter
T type Three Level Voltage Source Inverter
University: RK University
Completed Date: 2018
Abstract: Analysis and Compensation of Harmonics using Three-Level Voltage Source Inverter based Shunt Active Power Filter newlineKeywords: Shunt Active Power Filter, Three Level Voltage Source Inverter, Neutral Point Clamped, T type Three Level Voltage Source Inverter, Fast Fourier Transform, PI Based Current Control Method, Space Vector Current Control Method, Digital Signal Processor, PSIM. newline newlineBackground: newlineHarmonics issues are created in power systems due to the non-linear characteristics and fast switching of power electronics equipments. Power quality issues are becoming stronger because sensitive equipments may be damaged. Due to active power filters have been developed over the years to solve these problems to improve power quality. The concept of Filter proposed in 1971, Sasaki and Machida, to detect current harmonics using transformer. Harmonics current is drawn in opposite phases with the compensator. Active Filters are commercially available in market with different rating and different configuration. Also several patents are published on active power filters control methods and power topologies. newlineAim:This research work is carried out to compensate current harmonics using Neutral Point Clamped and T type three level voltage source inverter for non linear load. newlineMaterials and Methods: newlineNeutral Point Clamped and T type three level voltage source inverter power topologies are used for current harmonics compensation. Fast Fourier Transform algorithm has been used to predict reference current for shunt active power filter. It is found that FFT method is best among all other methods. FFT method has been discussed in the report. PI based current control and Space Vector Based Hysteresis current control methods are discussed in this thesis. DSP TMS320F28335 and TMS320F28377d are used for reference current prediction. Shunt active power filter is used for current harmonics compensation of non linear load. newlineResults and Discussion: newlinePSIM Simulation results and discussion included in this report for three level volt
Pagination: 
URI: http://hdl.handle.net/10603/233879
Appears in Departments:Faculty of Technology

Files in This Item:
File Description SizeFormat 
01_cover page.pdfAttached File267.06 kBAdobe PDFView/Open
02_certificate.pdf658.2 kBAdobe PDFView/Open
03_declaration.pdf433.94 kBAdobe PDFView/Open
04_acknowledgement.pdf185.05 kBAdobe PDFView/Open
05_table of contents.pdf324.13 kBAdobe PDFView/Open
06_list of tables.pdf438 kBAdobe PDFView/Open
07_list of figures.pdf404.18 kBAdobe PDFView/Open
08_ list of abbreviations.pdf545.21 kBAdobe PDFView/Open
09_abstract.pdf334.16 kBAdobe PDFView/Open
10_graphical abstract.pdf398.44 kBAdobe PDFView/Open
11_chapter 1.pdf499.4 kBAdobe PDFView/Open
12_chapter 2.pdf1.03 MBAdobe PDFView/Open
13_chapter 3.pdf1.64 MBAdobe PDFView/Open
14_chapter 4.pdf1.95 MBAdobe PDFView/Open
15_chapter 5.pdf1.19 MBAdobe PDFView/Open
16_chapter 6.pdf295.1 kBAdobe PDFView/Open
17_list of publication.pdf2.85 MBAdobe PDFView/Open
18_references.pdf571.14 kBAdobe PDFView/Open
19_appendix.pdf865.94 kBAdobe PDFView/Open
Show full item record


Items in Shodhganga are licensed under Creative Commons Licence Attribution-NonCommercial 4.0 International (CC BY-NC 4.0).