Please use this identifier to cite or link to this item:
http://hdl.handle.net/10603/230271
Title: | Investigational And Comparative Studies on Computational Accuracy of Current Treatment Planning Systems Used in Stereotactic Body Radiation Therapy SBRT for Lung Patients |
Researcher: | Chopra Kashmiri Lal |
Guide(s): | D.V.Rai |
Keywords: | Dose calculation algorithms, Monte Carlo, phantoms, SBRT, LQ-L Model. Life Sciences,Molecular Biology and Genetics,Biophysics |
University: | Shobhit University, Gangoh |
Completed Date: | 22-05-2018 |
Abstract: | The goals of this study are two-fold: (a) investigate the accuracy of five dose calculation algorithms by comparison against measurements performed in realistic homogeneous and heterogeneous phantoms, and (b) evaluate the impact of dose calculation algorithm used in lung SBRT patients. newlineThis dissertation has covered a broad spectrum of topics from fabrication of lung phantoms, measurements of doses in these phantoms, commissioning the virtual Novalis accelerator and CT scanner models in ADAC Pinnacle and Eclipse TPSs, and finally treatment planning of lung SBRT cases with MC, PB, CCC, AAA and AXB algorithms. newlineOverall, AXB algorithm is proved to be capable of calculating dose distributions in a variety of situations with an accuracy of within 3% as compared to MC calculations. Other algorithms, such as CCC and AAA, were within 5% of MC calculations newline |
Pagination: | 1-184 |
URI: | http://hdl.handle.net/10603/230271 |
Appears in Departments: | School of Engineering & Technology |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
02 contentsfigurestables&abbreviations1.docx | Attached File | 64.21 kB | Microsoft Word XML | View/Open |
04 appendices thesiskashmiri chopra.docx | 22.06 MB | Microsoft Word XML | View/Open | |
acknowledgement 4-5-18.docx | 23.5 kB | Microsoft Word XML | View/Open | |
certificate of plagiarism.docx | 93.93 kB | Microsoft Word XML | View/Open | |
chapter 1correct format3-31-18.docx | 8.47 MB | Microsoft Word XML | View/Open | |
chapter 2 correct format3-30-18.docx | 27.31 kB | Microsoft Word XML | View/Open | |
chapter 3correct format 3-31-18-1.docx | 41.6 kB | Microsoft Word XML | View/Open | |
chapter 4 correctformat 3-29-18.docx | 1.39 MB | Microsoft Word XML | View/Open | |
chapter 5 correct format 3-30-18.docx | 4.18 MB | Microsoft Word XML | View/Open | |
chapter 6 correct format 3-30-18.docx | 44.81 kB | Microsoft Word XML | View/Open | |
chapter 7 correct format 3-30-18.docx | 29.81 kB | Microsoft Word XML | View/Open | |
references correct format 3-30-18.docx | 41.31 kB | Microsoft Word XML | View/Open | |
x3wlb-x7x75.jpg | 92.04 kB | JPEG | View/Open |
Items in Shodhganga are licensed under Creative Commons Licence Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0).
Altmetric Badge: