Please use this identifier to cite or link to this item: http://hdl.handle.net/10603/175971
Full metadata record
DC FieldValueLanguage
dc.coverage.spatialThermal engineering
dc.date.accessioned2017-10-17T10:00:56Z-
dc.date.available2017-10-17T10:00:56Z-
dc.identifier.urihttp://hdl.handle.net/10603/175971-
dc.description.abstractnewline Solar air heaters systems are cheap and easy to maintain, but accompanies a disadvantage of low thermal efficiency because of low heat transfer coefficient between absorber plate and air in the duct. The application of sixty degree V ribs with symmetrical gaps wire roughness in a solar air heater appears to be worth for enhancing the performance of a solar air heater. It has been, therefore, taken up to investigate the effect of geometrical parameters of V ribs with symmetrical gap on the heat transfer and friction factor of the roughened duct. newline An experimental setup was designed and fabricated, and extensive experiments were conducted on a rectangular duct using an open loop with one broad wall of the duct heated with constant heat flux and roughened with V ribs with symmetrical gaps to investigate its heat transfer and friction characteristics. The range of roughness geometry and flow parameters considered in this experimental investigation are Reynolds number from 4000 to 18000, Number of gaps from 1 to 5, relative gap width from 1 to 5, Relative roughness pitch from 6 to 12 and Angle of attack from thirty to sixty degree. newline The V ribs with symmetrical gaps wire roughness duct with number of gaps of 3, relative gap width of 4, relative roughness height of 0.043, relative roughness pitch of 10 and angle of attack of sixty degree showed the maximum value of Nusselt number which was 3.67 times greater than that of the smooth duct. Similarly, the maximum value of the friction factor of V ribs with symmetrical gaps wire roughness duct was of the order of 3.67 times that of smooth duct. newlineThe correlations for Nu and f in terms of roughness and operating parameters are developed. It has been observed that on the basis of thermal efficiency criterion, a single set of roughness geometry parameters yielded optimum performance for the entire range of operating parameters and is given as Number of gaps 3, relative gap width 4, roughness pitch 10 and angle of attack sixty degree. newline
dc.format.extent248 pages
dc.languageEnglish
dc.rightsuniversity
dc.titleHeat Transfer and Friction Characteristics of V Rib with Symmetrical Gaps Roughened Solar Air Heater
dc.title.alternative
dc.creator.researcherMAITHANI RAJESH
dc.subject.keywordSolar air heater, artificial roughness, Nusselt number, Optimization
dc.description.note
dc.contributor.guideSAINI, J. S.
dc.publisher.placeDehradun
dc.publisher.universityUttarakhand Technical University
dc.publisher.institutionDepartment of Mechanical Engineering
dc.date.registered11-6-2012
dc.date.completed11-7-2017
dc.date.awarded13-10-2017
dc.format.dimensions290mm x 210mm x 30mm
dc.format.accompanyingmaterialCD
dc.source.universityUniversity
dc.type.degreePh.D.
Appears in Departments:Department of Mechanical Engineering

Files in This Item:
File Description SizeFormat 
01-title page.pdfAttached File43.4 kBAdobe PDFView/Open
02-certificate.pdf229.84 kBAdobe PDFView/Open
03-contents.pdf223.38 kBAdobe PDFView/Open
04-list of tables.pdf136.88 kBAdobe PDFView/Open
05-list of figures.pdf76.19 kBAdobe PDFView/Open
06-acknowlegdement.pdf81.17 kBAdobe PDFView/Open
07�chapter 1.pdf1.9 MBAdobe PDFView/Open
08-chapter 2.pdf1.07 MBAdobe PDFView/Open
09-chapter 3.pdf459.93 kBAdobe PDFView/Open
10-chapter 4.pdf276.17 kBAdobe PDFView/Open
11-chapter 5.pdf783.41 kBAdobe PDFView/Open
12-chapter 6.pdf988.61 kBAdobe PDFView/Open
13-chapter 7.pdf192.28 kBAdobe PDFView/Open
14-appendix.pdf162.4 kBAdobe PDFView/Open
15-references.pdf120.15 kBAdobe PDFView/Open
16-publications.pdf58.79 kBAdobe PDFView/Open


Items in Shodhganga are licensed under Creative Commons Licence Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0).

Altmetric Badge: