Please use this identifier to cite or link to this item: http://hdl.handle.net/10603/16155
Title: Dynamicmodelingand control strategies of upqcfor simultaneous voltage andcurrent compensation
Researcher: Annapandi P
Guide(s): Rajaram. M
Keywords: Current compensation
Dynamic modeling and control
Electrical engineering
Upload Date: 24-Feb-2014
University: Anna University
Completed Date: 01/12/2012
Abstract: Today utility network still significantly suffers from some low newlinepower quality factors. The poor reliability and quality of power supply may newlinecause many complex and serious problems. And high quality of power has newlinebeen more and more required by increasing number of sensitive loads. newlineHarmonics generated by nonlinear loads, voltage sag, and high frequency newlinecomponents caused by switched capacitors are some known sources seriously newlinedegrading the quality of supply in the power network. Power system can employ many attractive applications of power newlineelectronics technologies for power quality improvement. Voltage-source newlineconverter based custom power devices are increasingly being used in custom newlinepower applications to mitigate power quality problems in power distribution newlinesystems. One modern and very promising solution is the unified power quality newlineconditioner. newlineUnified Power Quality Conditioner(UPQC) is a custom power newlinedevice that consists of shunt and series converters connected back to back on newlinethe dc side and deals with load current and supply voltage imperfections. It newlinecan compensate for power quality problems such as voltage harmonics, newlinevoltage unbalance, voltage flickers, voltage sags, voltage swells, current newlineharmonics, current unbalance, reactive current, etc. The active power filtering newlinehas proven to be one of the best solutions for mitigation of major power quality problems. The operation of UPQC isolates the utility from current newlinequality problems of load and in the same time, isolates the load from voltage newlinequality problems of utility. The shunt active filter is utilized to overcome all current related newlineproblems, such as current harmonics, reactive current and current unbalance. newlineWhereas, all voltage related problems, such as voltage harmonics, voltage sag newlineand swell, and voltage unbalance, are handled by using the series active filter. The UPQC is controlled in such a way that the voltage at load bus is always newlinesinusoidal and has a desired magnitude. newline
Pagination: xix, 159p.
URI: http://hdl.handle.net/10603/16155
Appears in Departments:Faculty of Electrical and Electronics Engineering

Files in This Item:
File Description SizeFormat 
01_tiltle.pdfAttached File25.1 kBAdobe PDFView/Open
02_certificate.pdf5.65 kBAdobe PDFView/Open
03_abstract.pdf13.79 kBAdobe PDFView/Open
04_acknowledgements.pdf5.81 kBAdobe PDFView/Open
05_contents.pdf27.38 kBAdobe PDFView/Open
06_chapter1.pdf23.89 kBAdobe PDFView/Open
07_chapter2.pdf185 kBAdobe PDFView/Open
08_chapter3.pdf340.62 kBAdobe PDFView/Open
09_chapter4.pdf446.58 kBAdobe PDFView/Open
10_chapter5.pdf445.27 kBAdobe PDFView/Open
11_chapter6.pdf522.62 kBAdobe PDFView/Open
12_chapter7.pdf12.63 kBAdobe PDFView/Open
13_references.pdf19.26 kBAdobe PDFView/Open
14_publications.pdf6.28 kBAdobe PDFView/Open
15_vitae.pdf5.22 kBAdobe PDFView/Open
Show full item record


Items in Shodhganga are licensed under Creative Commons Licence Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0).

Altmetric Badge: